Search:
Display As PresentationsSessions
  Click Here for a Print-Friendly Version of this Page
Program#/Poster#:
2787/B422
Abstract Title:
Retinal Imaging and Wavefront Sensing in Mice
Presentation Start/End Time:
Tuesday, Apr 27, 2004, 5:15 PM - 7:15 PM
Location:
Hall BC
Reviewing Code:
228 optics – VI
Author Block:
S.A. Burns1, Y.Zhou2, C.P. Lin3, T.G. Bifano4, I.veilleux3, R.H. Webb1. 1Physiological Optics, Eye Research Institute, Boston, MA; 2Photonics Center, Boton University, Boston, MA; 3Wellman Laboratories of Photomedicine, Massachusetts General Hospital and HMS, Boston, MA; 4Manufacturing Engineering, Boston University, Boston, MA.
Keywords:
541 imaging methods (CT, FA, ICG, MRI, OCT, RTA, SLO, ultrasound),584 microscopy: light/fluorescence/immunohistochemistry,664 retina
Abstract Body:
Purpose: Mice are one of the major biological organisms for studying the genetic bases of human retinal disease. Unfortunately, the small size and consequently high refractive power of the mouse eye poses major problems for high resolution imaging. Previous approaches to imaging the mouse retina have adapted pre-existing imaging systems for the mouse. The purpose of the current study was to perform initial studies to guide the design and construction of a modern confocal adaptive optics SLO system for imaging the mouse retina.
Methods: A 30Hz confocal scanning laser ophthalmoscope was constructed. The major features of the system were 1) Use of 633 nm laser, and filters for both direct light imaging and near IR fluorescent label imaging. 2) An integrated Hartmann Shack wavefront sensor for measuring the aberrations of the mouse eye. 3) Provisions for incorporation of aberration control, 4) An avalanche photodiode for detection. 5) galvanometers based deflection system, 6) A very large range of defocus compensation. 7) A corneal contact lens was used to maintain anterior eye clarity. The system visualizes the eye through a 1 mm pupil.
Results: Mice retina were successfully imaged, with good contrast of the major retinal vessels and visualization of nerve fibers. A major problem was that the mice used had a wide range of emmetropia, ranging from slightly myopic when fitted with the corneal contact lens to 20 diopters hyperopic. The HS sensor in its current configuration is very useful for determining best focus, and higher order aberrations on the mouse eyes measured to date are low.
Conclusions: The current system has some problems with reflections, but has proven useful for imaging and for testing out the initial stages of the imaging system design.
Commercial Relationship:
 S.A. Burns, None; Y. Zhou, None; C.P. Lin, None; T.G. Bifano, None; I. veilleux, None; R.H. Webb, None.
Grant Identification:
R01 EY14106
 
 
For optimum use, we recommend you use Internet Explorer 6.0. Click here to download IE 6.0. Mozilla is not currently supported. For a full list of supported browsers, please click here.
Preparation of the ARVO 2004 Online Annual Meeting Abstract Search and Program Planner is supported through an unrestricted educational grant by Pfizer Ophthalmics.
Pfizer Ophthalmics
Click Logo to View Website
© Association for Research in Vision and Ophthalmology, Inc., all rights reserved.
Permission to reproduce any part of an abstract, access the version of record at www.iovs.org.
ARVO Disclaimer
Technical support phone: (217) 398 - 1792 Email: support@abstractsonline.com
The Online Abstract Submission and Invitation System
© 1996 - 2010 Coe-Truman Technologies, Inc. All rights reserved.